Epiroc Rock Drill Low Impact Pressure – Troubleshooting Guide
Mastering Hydraulic Drifter Performance for Mining & Construction
Experiencing low impact pressure on your Epiroc or Atlas Copco rock drill? This issue directly correlates to reduced penetration rates, increased drill steel consumption, and potential overheating. This guide outlines the systematic approach to diagnosing and resolving low percussion pressure issues, ensuring your fleet remains operational.
Figure 1: Simplified visualization of Rock Drill Hydraulic Inputs.
1. Identifying the Symptoms
Before disassembling components, confirm the symptoms using the drill rig's dashboard or external pressure gauges:
Slow Penetration Rate: The drill bit is not advancing as expected in standard rock conditions.
Low Gauge Reading: The percussion pressure gauge reads significantly below the recommended operating pressure (e.g., below 180-200 bar depending on the model).
Excessive Hose Vibration: Jumping hydraulic hoses often indicate accumulator failure.
High Hydraulic Oil Temperature: System bypassing oil generates excess heat.
2. Common Causes & Solutions
A. Accumulator Faults (Nitrogen Pressure)
The most common cause of fluctuating or low impact pressure is improper Nitrogen (N2) charge in the accumulators. The accumulator acts as a battery, storing energy for the piston stroke.
| Component | Potential Issue | Corrective Action |
|---|---|---|
| Intake Accumulator | Bladder rupture or Low N2 pressure. | Check membrane. Recharge N2 to spec (typically 60-70% of working pressure). |
| Return Accumulator | Damaged diaphragm causing backpressure. | Inspect and replace diaphragm if oil is present on air side. |
B. Hydraulic Pump & Supply Issues
If the impact pressure is low, the source might not be the drill itself, but the carrier rig.
Pump Efficiency: Perform a flow meter test on the variable displacement pump. A worn pump cannot maintain pressure under load.
Relief Valve Settings: Ensure the main pressure relief valve is not set too low, causing oil to dump back to the tank prematurely.
LS (Load Sense) Line: Check for blockages in the LS signal line. If the pump doesn't receive the signal to stroke up, it remains in standby pressure.
C. Internal Rock Drill Leakage
Internal bypassing within the rock drill body prevents pressure buildup.
Piston Seals: Worn piston guides or seals allow high-pressure oil to leak directly to the return line.
Control Valve (Distributor): Scratches or wear on the control valve spool can disrupt the percussion cycle frequency.
3. Advanced Diagnostics: The Dampening System
On modern Epiroc drifters, the dampening pressure serves as a pilot signal for percussion. If the dampening pressure is too low (indicating poor feed force or bit contact), the rock drill will not engage full impact pressure to protect the shank adapter.
Troubleshooting Step: Verify the dampening pressure is within the green zone (usually 35-40 bar). If dampening is low, check the dampening accumulator and constant flow valve.
4. Preventive Maintenance Checklist
To avoid recurring low pressure issues, adhere to the following schedule:
Daily: Check for external oil leaks around the shank adapter and side bolts.
Weekly: Check Accumulator N2 gas pressure.
Every 500 Hours: Inspect shank adapter wear and flushing head seals.
Every 1000 Hours: Schedule a complete drifter overhaul (seals, diaphragms, bearings).